On the Resolution of Magnetotelluric Horizontal Magnetic Inter-station Transfer Function

Clicks: 6
ID: 316537
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #184 of 238 articles by views in geophysical journal international

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 238 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Summary The horizontal magnetic inter-station transfer function (M) offers distinct advantages in magnetotelluric (MT) studies due to its reduced susceptibility to shallow galvanic distortions. While its utility in constraining subsurface conductivity through 2D inversions is established, its resolution characteristics in three-dimensional (3D) scenarios—particularly regarding depth sensitivity and lateral recovery—remain poorly quantified. Here, we conduct a systematic investigation of M through 3D forward modelling, sensitivity analysis, and inversion of synthetic models, followed by a validation using long-period MT array data from the Eastern Pamir. Key findings reveal: (1) M exhibits response patterns analogous to the impedance tensor (Z), with an inverse component correspondence where diagonal elements of Z align with off-diagonal elements of M; (2) Reference station placement critically controls the inversion performance of M—locations above conductive anomalies distort anomalous currents and degrade data fit, whereas resistive homogeneous backgrounds enhance lateral resolution; (3) M resolves shallow anomalies with lateral boundary definition and resistivity contrast recovery superior to those of Z and the tipper (T) in sparse arrays; (4) Sensitivity tests indicate that M provides limited resolution for deep structures beyond the effective inductive scale, where its recovery capability diminishes significantly compared to Z; (5) Application to field data demonstrates that incorporating M improves the resolution of complex shallow structures and enhances the fit of Z data, with the joint inversion of Z + M + T yielding the most robust electrical model. We recommend using multiple reference stations for field data inversion to mitigate the impact of variations in reference site locations. This work establishes a quantitative framework for deploying M in field surveys and 3D inversions.
Reference Key
openalex_W7163996698 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Gang Wen, Bo Yang, Xiaolei Wu, Lian Liu, Yixian Xu
Journal geophysical journal international
Year 2026
DOI
10.1093/gji/ggag217
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.