Implementation and evaluation of continuous infusion automatic scheduled dispensing leveraging infusion pump integration

Clicks: 1
ID: 316367
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal

Ranked #99 of 143 articles by views in American journal of health-system pharmacy : AJHP : official journal of the American Society of Health-System Pharmacists

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 143 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
PURPOSE: This project aimed to develop, implement, and evaluate an automatic scheduled dispensing workflow for titratable and nontitratable continuous infusions leveraging infusion pump integration within the electronic health record. SUMMARY: Infusion pump integration allows the development of a scheduled dispensing workflow, in which the electronic health record automatically schedules the next dispense for a continuous infusion based on the administered rate and volume of the medication. This functionality streamlines pharmacy and nursing workflows by eliminating the need for manual re-dispensing pursuant to manual tracking or nursing-to-pharmacy electronic requests. An automatic scheduled dispensing workflow was developed and piloted at a select pharmacy, with subsequent expansion throughout the health system. A retrospective, descriptive analysis was performed comparing the following data points before and after implementation: total dispenses, bags returned, and in-basket messages for continuous infusion dispenses. At the pilot site and the expansion sites, after implementation the number of in-basket messages per continuous infusion dispense decreased by 49% and 65%, respectively. An increase in the number of medication returns and the number of wasted bags per continuous infusion dispense was observed for both the pilot site and the expansion sites. CONCLUSION: A continuous infusion scheduled dispensing workflow was successfully implemented within a health system. This workflow resulted in a reduction in nursing-to-pharmacy in-basket message communication per dispense, with an increase in returns and waste.
Reference Key
openalex_W7163883833 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Jennifer Booth, Jessica Brimmer, Anuj Thirwani, Marissa Nelson, Ben Lopez, Charlotte Forshay
Journal American journal of health-system pharmacy : AJHP : official journal of the American Society of Health-System Pharmacists
Year 2026
DOI
10.1093/ajhp/zxag156
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.