Simultaneous Determination of Four Per- and Polyfluoroalkyl Substances (PFAS) in DHA Products using LC-MS/MS for Quality Control and Risk Assessment

Clicks: 1
ID: 315587
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal

Ranked #324 of 358 articles by views in journal of aoac international

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 358 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
BACKGROUND: Docosahexaenoic acid (DHA) is a critical dietary supplement for vulnerable populations (e.g., infants, pregnant women), but contamination by per- and polyfluoroalkyl substances (PFAS)-persistent "forever chemicals"-poses potential health risks. Currently, no standardized methods exist for PFAS detection in DHA products, hindering quality control and risk assessment. OBJECTIVE: To develop and validate a sensitive LC-MS/MS method for simultaneous determination of four PFAS (PFOA, PFODA, PFOS, and PFBS) in DHA matrices (algal oil and fish oil) and support product safety evaluation. METHODS: Samples were extracted with 50% methanol/acetonitrile (v/v) via ultrasonication (40 °C, 20 min), followed by centrifugation and filtration. Chromatographic separation was achieved on a Phenomenex Kinetex F5 column (100 × 3.0 mm, 2.6 μm) with gradient elution (mobile phase: 2 mmol/L ammonium formate aqueous solution-methanol) in 12 min. Detection was performed via negative electrospray ionization (ESI-) in multiple reaction monitoring (MRM) mode. Method validation included linearity, limits of detection (LODs)/quantitation (LOQs), accuracy, precision, matrix effects, and stability. Thirteen commercial DHA products (11 algal oil, 2 fish oil) were analyzed. RESULTS: Linearity (r ≥ 0.99) were achieved for PFAS; LODs/LOQs: 0.02/0.04 ng/mL. Recoveries at three spiking levels (0.1, 0.5, 1.0, 1.5 ng/mL) were ranged from 92.1%-108.4%, with RSDs of 2.8%-5.6%. Matrix effects were effectively corrected via matrix-matched calibration. Trace PFAS were detected in 3/13 samples, all below regulatory limits. CONCLUSIONS: The developed method is reliable for routine PFAS detection in DHA matrixes, providing practical technical support for quality control and risk assessment for DHA supplements for vulnerable populations. HIGHLIGHTS: Rapid (12 min), sensitive, and applicable to both algal oil and fish oil matrixes.
Reference Key
openalex_W7163162402 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Jiayi Zhang, Yanping Cao, Xuee Xi, Chaoqiang Xiao, Li Zhu
Journal journal of aoac international
Year 2026
DOI
10.1093/jaoacint/qsag045
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.