Near-point-of-care diagnosis of tuberculosis with LyocartE MTB Assay: a multicentre diagnostic accuracy study

Clicks: 1
ID: 315280
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal

Ranked #488 of 530 articles by views in Clinical infectious diseases : an official publication of the Infectious Diseases Society of America

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 530 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Background Tuberculosis (TB) continues to pose a major threat to global public health. The development of rapid near point-of-care diagnostics utilizing non-sputum specimens is critical for advancing TB control efforts. Methods In this multicentre prospective diagnostic accuracy study, 689 consecutive individuals with presumptive TB were enrolled from three sites in China. Sputum and tongue swab specimens were collected from all participants for index testing with the LyocartE assay and comparator testing with Xpert Ultra, smear microscopy, and culture. The diagnostic performance of LyocartE for active TB was evaluated against two pre-defined reference standards: Xpert Ultra results and the composite microbiological reference (MRS) standard. Results Among the 689 participants analyzed, LyocartE on sputum demonstrated a sensitivity of 95.2% and specificity of 98.6% against the MRS. For tongue swab specimens compared to sputum Xpert Ultra results, LyocartE sensitivity was 87.4% with a specificity of 99.7%. When evaluated against MRS for tongue swabs, sensitivity was 84.1% and specificity was 99.7%. The diagnostic accuracy of LyocartE remained robust across specimen types, clinical symptoms, and comorbidities. Strong correlation was observed between LyocartE and Xpert Ultra Ct values (sputum: r=0.7476, P<0.0001; tongue swab: r=0.5607, P<0.0001). Conclusion The near point-of-care LyocartE assay offers rapid and accurate TB detection from both sputum and tongue swab specimens. Its performance is comparable to Xpert Ultra on sputum and demonstrates improved sensitivity for tongue swab analysis. Further evaluation in asymptomatic and paucibacillary populations is urgently required to confirm these findings.
Reference Key
openalex_W7162763397 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Zichun Ma, Xiaoying Yu, Yanhong Yu, Yilin Wang, Jin Shi, Wei Jing, Yuanyuan Shang, Weicong Ren, Hui Li, Tianhong Zhang, Baoqing Zhang, Jiao Sun, Xin Ma, Liang Li, Yu Pang
Journal Clinical infectious diseases : an official publication of the Infectious Diseases Society of America
Year 2026
DOI
10.1093/cid/ciag342
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.