The Determination of potentially toxic elements (Arsenic, Cadmium, Mercury, and Lead) in Hemp (Cannabis sativa L.) from using Inductively Coupled Plasma Optical Emission Spectroscopy (ICP OES)
Clicks: 1
ID: 315239
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
0.0
/100
1 views
0 readers
AI Quality Assessment
Not analyzed
Readership in this journal
Ranked #353 of 359 articles by views in journal of aoac international
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 359 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Abstract Background Hemp (Cannabis sativa L.) readily accumulates potentially toxic elements (PTEs) from soil. PTE exposure is linked to cancer, nephrotoxicity, and neurotoxicity. Non-intoxicating hemp products in New Jersey are not subject to mandatory PTE testing, posing a consumer safety risk. Objective This study presents a single-laboratory validation of an ICP OES method for the determination of As, Cd, Pb, and Hg in hemp, evaluated against AOAC SMPR 2020.001 performance criteria. Methods Ground hemp (0.125 g) was digested using HNO3/HCl/H2O2 (190 °C, 20 min) and diluted to 50 mL. Samples were analyzed on an Agilent 5800 ICP OES with a seven-point calibration (1–100 μg/L), Au/Sc internal standards, and KHP carbon for matrix matching. Results Spike recoveries for Cd (92.7%) and Pb (96.2%) met AOAC SMPR 2020.001 criteria (80–115%). Mercury recovery (47%) fell below acceptance limits due to matrix suppression and volatility losses. The As LOD (0.807 μg/g) exceeded sample concentrations in most specimens. LOQ values for all four elements exceeded the SMPR 2020.001 threshold of 10 µg/kg (0.01 µg/g). Calibration linearity was confirmed for all analytes (r ≥ 0.995). Conclusion Partial validation was achieved: Cd and Pb demonstrated acceptable accuracy and repeatability, but LOQ criteria were not met for any analyte. ICP OES is not suitable for Hg or As at regulatory trace levels; ICP MS is recommended for these elements. This method offers a cost-effective screening tool for Cd and Pb in hemp. Highlights This study presents the first single-laboratory ICP OES validation for PTEs in hemp under AOAC SMPR 2020.001. Cd and Pb met accuracy and repeatability criteria; As and Hg did not meet sensitivity requirements. ICP MS is recommended for regulatory As and Hg testing in hemp.
| Reference Key |
openalex_W7162768870
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Esha G Sachdev, Ghazal A Khan |
| Journal | journal of aoac international |
| Year | 2026 |
| DOI |
10.1093/jaoacint/qsag044
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.