Polarisation and Faraday rotation measure imaging at metre wavelengths with sub-arcsecond resolution: a foundational calibration strategy
Clicks: 1
ID: 315057
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
0.0
/100
1 views
0 readers
AI Quality Assessment
Not analyzed
Readership in this journal
Ranked #787 of 908 articles by views in monthly notices of the royal astronomical society
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 908 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Abstract Low-frequency radio polarimetric observations provide a powerful probe of magnetic fields in astrophysical sources and the intervening medium, as well as magnetospheric emission from compact objects such as pulsars, magnetically active stars, brown dwarfs, and planetary aurorae. With baselines of up to 2000 km, LOFAR offers a unique opportunity to study the low-frequency polarised Universe at sub-arcsecond resolution. However, polarimetric studies with LOFAR have so far been limited to angular resolutions of ~6″, resulting in stronger beam depolarisation. Here we present a calibration strategy that enables full-resolution polarimetric imaging with the LOFAR pan-European array. Our method applies full-Jones corrections to the international stations using an in-field unpolarised calibrator. In addition, when a sufficiently bright polarised source is present in the field, multi-epoch observations can be aligned in Faraday depth using a visibility-based correction that accounts for polarisation angle and rotation measure offsets. This approach enables deeper combined imaging and deconvolution. We apply this strategy to the LOFAR ELAIS-N1 field, combining four 8-h observations for a total integration time of 32 h. At 0.3″ resolution, we detect two previously known polarised sources identified in lower-resolution studies, resolve additional polarised components, and localise emission regions with sub-arcsecond precision. We also identify a new polarised source and detect circularly polarised emission from the binary M-dwarf system CR Draconis, measuring its proper motion across epochs. These results demonstrate that sub-arcsecond polarimetry at metre wavelengths is now feasible with LOFAR, opening new science opportunities in the LOFAR2.0 era.
| Reference Key |
openalex_W7162553904
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | R J van Weeren, J M G H J de Jong, X K Le Saux, V A Chakawri, Q W E van Zegveld, D de Jong, S P O’Sullivan, F Sweijen, V H Mahatma, E De Rubeis, L K Morabito, D Alonso-López, A Bonafede, C Horellou, M van der Wild |
| Journal | monthly notices of the royal astronomical society |
| Year | 2026 |
| DOI |
10.1093/mnras/stag992
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.