Numerical study on dual-frequency ultrasonic enhancing cavitation effect based on bubble dynamic evolution.

Clicks: 192
ID: 31431
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #53 of 59 articles by views in ultrasonics sonochemistry

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Ultrasonic cavitation is a physical dynamic phenomenon of bubbles inflation, compression, and collapse in liquid. A dual-frequency ultrasonic cavitation dynamics model is established in this paper to investigate dynamic evolution of bubble under single and dual frequency ultrasonic modes. The variation of bubble radius, pressure, energy, temperature, and number of water vapor molecules inside the bubble in single and dual frequency ultrasonic modes are analyzed, respectively. The results show the oscillation of cavitation bubbles is more unstable and easier to collapse in dual-frequency ultrasound field than those in single-frequency ultrasound field. With the increase of the ultrasonic frequency, cavitation effect is weakened due to the shortage of oscillation period. Under the same ultrasonic power, the maximums of bubble radius, pressure, and water vapor molecules number inside the bubble in the dual-frequency mode are larger than those in the single-frequency mode. Under the ultrasonic excited by 50 kHz + 70 kHz, the maximum bubble radius and pressure can reach 36.061 μm and 2285.9 MPa, respectively, which are much larger than 18.183 μm, 730.61 MPa at 50 kHz and 14.576 μm, 332.25 MPa at 70 kHz. The calculation results of three different frequency combinations (30 kHz + 50 kHz, 40 kHz + 60 kHz and 50 kHz + 70 kHz) indicate dual-frequency ultrasound can significantly enhance the cavitation effect.
Reference Key
ye2019numericalultrasonics Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Ye, Linzheng;Zhu, Xijing;Liu, Yao;
Journal ultrasonics sonochemistry
Year 2019
DOI
S1350-4177(19)30730-8
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.