Intimate encapsulation of non-planar electrodes via a viscoplastic interlayer

Clicks: 17
ID: 314237
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #309 of 423 articles by views in national science review

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 423 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Implantable electronics often adopt non-planar electrodes to resolve the conflict between conductivity and deformability. Encapsulation of these electrodes becomes a critical challenge for conventional elastic seals due to the elastic-contact-induced interfacial voids and consequential fluid ingress. Here, we present a viscoplastic interlayer that can adapt to the three-dimensional structures of non-planar electrodes, resulting in intimate contact and hermetic encapsulation. This interlayer is a polymeric composite that consists of a long-chain polyisobutylene as the matrix, a short-chain polyisobutylene as the plasticizer, and maleic anhydride-grafted polypropylene as the foreign domains. Its viscoplasticity originates from the chain slippage and permanent disentanglement of the long-chain polyisobutylene, promoted by the plasticizers and confining domains, respectively. When synergized with covalent bonding, the interlayer derives defect-free interfaces between the sealing elastomer and various non-planar electrodes, such as microwires, micropillars, and serpentine electrodes. This intimate encapsulation stabilizes the signal-to-noise ratio of an electromechanical device for 50 weeks in acidic, neutral, and alkaline solutions and extends the in vivo duration of signal fidelity for stretchable bioelectronics to a record 45 weeks. This viscoplastic interlayer provides fruitful implications for improving the long-term stability of implantable bioelectronics.
Reference Key
openalex_W7161837725 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal national science review
Year 2026
DOI
10.1093/nsr/nwag297
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.