Significant or Not? The Impact of Randomisation During Data Reduction on Confirming a New Pulsating Ultraluminous X-ray Source Candidate in Centaurus A
Clicks: 2
ID: 313385
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
0.3
/100
2 views
1 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #901 of 913 articles by views in monthly notices of the royal astronomical society
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 913 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Abstract We report the discovery of a new candidate pulsating ultraluminous X-ray source (PULX) in NGC 5128 (Centaurus A). The candidate, 4XMM J132542.2–425943, is a transient source, identifiable as a clear X-ray point source for ~8 months in 2014, during its only major recorded outburst. The source flux exceeded 10−12 erg cm−2 s−1 at the peak of the outburst. The long-term light curve of 4XMM J132542.2–425943 shows two further, less luminous detections in 2017 and 2024, but was otherwise in quiescence. This behaviour is similar to the class of pulsating transients with outbursts that reach the ultraluminous regime, which includes the well-studied Galactic PULX, Swift J0243.6+6124. However, 4XMM J132542.2–425943 displays a soft X-ray spectrum, making this source distinct from the existing population of PULXs, which typically show hard spectra below 10 keV. We searched the 2014 XMM-Newton observations for X-ray pulsations, revealing coherent, sinusoidal X-ray pulsations at a frequency of 1.27 Hz in one XMM-Newton observation (ObsID 0724060801), at a marginal significance. For this signal we measure a pulsed fraction, PF ≈ 15 − 17 % and $\dot{f}~\sim ~4~\times ~10^{-9}$ Hz s−1. However, we find that the intrinsic randomisation employed by XMM-Newton’s Science Analysis Software, XMM-SAS, during the data reduction procedure introduces considerable uncertainty in the strength of our marginal pulsations, which varies significantly between consecutive data reduction iterations. We explore the impact of this randomisation and demonstrate that it can generate widespread false positives and false negatives, which, in the context of PULX searches, may cause viable candidates to be unnecessarily discarded or vice versa.
| Reference Key |
openalex_W7161236796
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Amy H Knight, T. P. Roberts, Callum Potter, Alistair T Pagan, D. J. Walton |
| Journal | monthly notices of the royal astronomical society |
| Year | 2026 |
| DOI |
10.1093/mnras/stag936
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.