The Anatomic Feasibility of Thoracic Branched Endoprosthesis in the Treatment of Blunt Thoracic Aortic Injury
Clicks: 1
ID: 310324
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
0.0
/100
1 views
0 readers
AI Quality Assessment
Not analyzed
Readership in this journal
Ranked #488 of 490 articles by views in Frontiers in surgery
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 490 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Introduction: Blunt thoracic aortic injury (BTAI) is one of the leading causes of death among trauma patients who sustain high impact thoracic trauma with rapid deceleration. Thoracic endovascular aortic repair (TEVAR) is indicated in high grade injuries and requires a management strategy for the left subclavian artery (LSA). Gore TAG thoracic branch endoprosthesis (TBE) is a newly approved TEVAR device for to maintain LSA patency utilizing a side branch with reported use in acute indications. The anatomic suitability of this device for a population of BTAI patients and optimal inventory for off-the-shelf emergent repairs has not been reported. Methods: A retrospective analysis of 66 patients admitted to a Level 1 Trauma Center who sustained BTAI between January 2011 and December 2023 and underwent TEVAR was performed. Computed tomography imaging was analyzed on all patients to determine the suitability for repair according to instructions for use (IFU) criteria of the manufacturer. Results: The distance between the LSA and the injury was less than 2 cm in 59% of patients, representing a possible indication for TBE. The average injury distance in this cohort was 9mm from the LSA, with 82% of these patients meeting IFU requirements for TBE and 18% requiring standard TEVAR. For patients who met TBE graft requirements, 28 mm, 31 mm, and 34 mm aortic components fit 76% of patients and 10 mm and 12 mm subclavian branches fit 87% of patients. Patients who did not meet IFU requirements for TBE were sized for standard TEVAR with 26 mm, 31 mm, and 34 mm grafts treating 66% of patients. Conclusions: This study demonstrates key anatomic considerations and models the suitability and optimal TBE inventory drawn from a real-world population of BTAI patients. Despite a vast device catalog for TEVAR, this study demonstrates that carrying three TBE aortic components, two TBE subclavian components, and three standard TEVAR sizes would treat 71% of BTAI patients.
| Reference Key |
imported_1768925917_696faadd0262b
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Causey, Marlin |
| Journal | Frontiers in surgery |
| Year | Year not found |
| DOI |
10.3389/fsurg.2025.1667618
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.