[Simultaneous analysis of five organic acids in aqueous, lotion, and cream cosmetics by capillary electrophoresis].

Clicks: 432
ID: 31026
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #7 of 69 articles by views in se pu = chinese journal of chromatography

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
An indirect ultraviolet detection method for simultaneous analysis of five organic acids by capillary electrophoresis was established. The concentration of the tetradecyltrimethylammonium bromide (TTAB) surfactant in the background electrolyte solution and the pH of the solution were optimized. Five organic acids formic acid, malic acid, citric acid, glycolic acid, lactic acid were effectively separated from each other within 6 min with an electrolyte solution (15 mmol/L potassium hydrogen phthalate and 0.4 mmol/L TTAB, pH 5.6) under conditions of -15 kV, 25℃, and 254 nm, while the injection pressure was 5 kPa and the injection time was 5 s. The linear ranges were 15-600 mg/L, 30-800 mg/L, 20-700 mg/L, 40-500 mg/L, and 30-5000 mg/Lfor formic acid, malic acid, citric acid, glycolic acid, and lactic acid, respectively, with correlation coefficients of 0.9983-0.9998. The detection limits were between 0.1 μg/g and 2.0 μg/g. The method can be used for the detection of five organic acids in three types of cosmetics including aqueous, lotion and cream. At three spiked levels, the recoveries of organic acids were between 95.0% and 101.6%, and relative standard deviations (RSDs) were within 2.0%. The proposed method is easy, rapid, environment friendly, and sensitive with good reproducibility. It can be used for the monitoring of five organic acids in the production and storage of cosmetics including aqueous, lotion and cream.
Reference Key
wang2019simultaneousse Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Wang, Huimin;Sun, Miao;Qu, Feng;
Journal se pu = chinese journal of chromatography
Year 2019
DOI
10.3724/SP.J.1123.2019.01021
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.