Mapping the anatomic distribution of digital artery perforators: a pilot cadaveric study for reconstructive flap surgery

Clicks: 1
ID: 310243
2025
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal

Ranked #419 of 490 articles by views in Frontiers in surgery

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 490 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
IntroductionFingertip injuries, particularly crush injuries, are among the most common hand injuries across all age groups. The Digital Artery Perforator (DAP) flap has become a preferred option for fingertip reconstruction due to its simplicity, reliability, and minimally invasive nature compared to techniques like cross-finger or thenar flaps. Despite its growing use, detailed documentation of DAP patterns crucial for effective surgical planning is limited, especially in relation to demographic factors. This study aimed to map the anatomical distribution of DAPs and provide preliminary local data.MethodsSixteen triphalangeal digits (excluding thumbs) from four female cadaveric upper limbs (mean age: 83 years) were injected with gelatin dye and dissected to expose DAPs. Photographs of the dissections were analyzed for DAP distribution across hand laterality, digit type, finger sides, phalanges, and phalanx thirds.ResultsA total of 226 perforators were identified. On average, there were 57 DAPs per hand, 14 per digit, seven per finger side, five per phalanx, and two per phalanx third. Each phalanx contained at least one DAP, with an average of two DAPs per phalanx per finger side.ConclusionHigh-density areas of DAP distribution suggest consistent anatomical patterns, supporting reliable DAP flap design. The findings indicate that preoperative Doppler ultrasound may not be necessary for flap planning, potentially simplifying surgical workflows. While limited by a small sample size, this study offers foundational insights for improving fingertip reconstruction and highlights the need for further research into DAP patterns and their clinical applications.
Reference Key
imported_1768925689_696fa9f925f86 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Dhumale, Sameer
Journal Frontiers in surgery
Year 2025
DOI
10.3389/fsurg.2025.1677597
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.