Potential of methylene blue fluorescence angiography for multiple intraoperative tissue perfusion assessments in plastic and reconstructive surgery: current knowledge and prospects
Clicks: 2
ID: 310235
2025
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
0.3
/100
2 views
1 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #479 of 490 articles by views in Frontiers in surgery
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 490 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The expansion of (minimally invasive) surgical techniques has led to the development of advanced tools, including high-definition visual systems and fluorescence-guided surgery (FGS), enhancing surgeons' performance and patient safety. FGS employs near-infrared light and fluorophores like indocyanine green (ICG) for intraoperative imaging to improve anatomical navigation and decision-making. Recently, an increasing number of fluorescence imaging systems have shown capability in visualizing methylene blue (MB), which has an excitation peak at 700 nm, and its potential role in perfusion assessment. A recent study has highlighted MB's advantage over ICG due to its shorter washout time, enabling repeated intraoperative perfusion assessments using a dose of 0.5 mg/kg in a porcine model. This characteristic may be particularly beneficial in plastic and reconstructive surgery involving free (chimeric) flaps, pedicled skin flaps, pedicled intestinal transplants, and mastectomy skin flaps, where perfusion assessment can be critical at multiple stages. Therefore, we highlight some examples of flap reconstructions in this technical note. Important to know, MB is considered safe within the therapeutic doses (<2 mg/kg). However, it is contraindicated in certain patients, including those who are pregnant, have renal insufficiency, are on specific serotonin medications and some rare deficiencies. As dual-wavelength fluorescence imaging systems compatible with both ICG and MB advance, there is growing interest in the potential of MB for (multiple) flap perfusion assessment(s) in plastic and reconstructive surgery, building on promising research in bowel perfusion.
| Reference Key |
imported_1768925675_696fa9ebbefe7
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Schols, Rutger M. |
| Journal | Frontiers in surgery |
| Year | 2025 |
| DOI |
10.3389/fsurg.2025.1681731
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.