A New Approach for Assessment of Clubfoot Treatment Using Non-Radiological Scanner Coupling Finite Element
Clicks: 2
ID: 310184
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
0.3
/100
2 views
1 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #428 of 490 articles by views in Frontiers in surgery
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 490 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Introduction: To develop a new approach for clubfoot treatment assessment using a non-radiological scanner and finite element method (FEM) simulation techniques, which could eliminate the 8% risk of X-ray exposure, as well as evaluate the strain at the Achilles tendon.Methods: The geometry of the clubfoot was acquired by using an optical-light-based scanner. The 3D model was generated from the geometry and exported to finite element simulation software. The contact and large deformation model was established to 13 simulate the angle correction of the Ponseti therapy. The strain and pseudo strain 14 rate were calculated from the simulation results and analysed for assessment. Results: The simulated stress distribution showed the stress concentration around the Achilles tendon, which coincides with the actual situation. The strain and pseudo strain rate were analysed with the correction angle, which matches the three-stage casting of Ponseti therapy. The result suggested the intermediate angle correction casting was 40% and 87% of the correction process. The recommended correction angles for coronal, axial, and sagittal axes were α=17.2˚, β=-2˚, and γ=13.2˚ for the first casting, and α=35.6˚, β=-4.4˚, and γ=25.4˚ for the second casting. Conclusion: Using the proposed approach has led to good correlation between the simulation results and the actual situation. It was feasible to use a non-radiological scanner coupled with FEM to evaluate the clubfoot treatment, which eliminates the risk of X-ray exposure for infants.
| Reference Key |
imported_1768922308_696f9cc498bc5
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Li, Fujiang |
| Journal | Frontiers in surgery |
| Year | Year not found |
| DOI |
10.3389/fped.2026.1777412
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.