3D printing-assisted triple-vessel in situ fenestration combined with a diameter-restricting technique for a complex giant aortic arch aneurysm in an octogenarian: a case report and technical innovation

Clicks: 1
ID: 309948
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal

Ranked #209 of 490 articles by views in Frontiers in surgery

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 490 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
BackgroundAortic arch aneurysms involving branch vessels traditionally require open surgery with cardiopulmonary bypass, which poses prohibitive risks for octogenarians with complex comorbidities. This case demonstrates the successful application of total endovascular aortic repair (TEVAR) with three dimensional (3D) printing-assisted triple-vessel in situ fenestration and a diameter-restricting technique in an 85-year-old patient with a giant (9.0 cm) aortic arch aneurysm involving the left subclavian artery.Case presentationThe involvement of the three arch branches (brachiocephalic trunk, left common carotid artery, and left subclavian artery) necessitated precise revascularization. In comparison with traditional in situ fenestration, 3D printing-guided ex vivo fenestration enabled pre-release stent modeling on a 1:1 aortic arch replica (error <1 mm), allowing anatomically tailored fenestration positioning and eliminating blind puncture-related complications. A proximal stent diameter-restricting technique addressed the challenging anchoring zone gradient (33.6 → 27.3 mm), improving stent apposition and reducing type I endoleak risk. Intraoperative multiaccess reconstruction (femoral/axillary/cervical approach) achieved complete aneurysm exclusion. Postoperative computed tomography angiography on day 4 confirmed patent branches and absence of endoleaks, while 6-month follow-up demonstrated stable stent position and no neurological complications.ConclusionThis case highlights that TEVAR with 3D printing-assisted ex vivo fenestration and a diameter-restricting technique can serve as a viable alternative to open surgery for high-risk octogenarians with complex aortic arch aneurysms, overcoming traditional limitations of in situ fenestration while preserving cerebral perfusion. Further studies are warranted to validate this approach in larger populations.
Reference Key
imported_1768907596_696f634c6eefd Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Zhang, Yongheng
Journal Frontiers in surgery
Year 2026
DOI
10.3389/fcvm.2025.1650003
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.