In Vivo Evaluation of a Biodegradable Intraanastomotic Membrane in a Porcine Model

Clicks: 3
ID: 309911
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #155 of 490 articles by views in Frontiers in surgery

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 490 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Background: Anastomotic leakage (AL) represents one of the most serious complications in gastrointestinal surgery, with reported incidence rates of up to 26 %. Despite advancements in surgical techniques, early detection of AL remains challenging, and no reliable real-time monitoring system is currently available. In this study, we investigated a resorbable polydioxanone (PDO) membrane as a potential substrate for future sensor integration, aiming to facilitate real-time monitoring of anastomotic healing. Methods: In eight German Landrace pigs, 34 ileal side-to-end stapler anastomoses were examined: GM1 (n = 7), GM2 (n = 10), and controls (n = 17). Membrane stability was monitored after implantation, while adhesion formation, burst pressure, and histology were assessed on postoperative day 7. Results: Both membrane geometries showed robust stability, with good anchorage of the large spokes within the anastomosis. Geometry 1 (GM1) exhibited higher burst pressure than Geometry 2 (GM2) (193 ± 43.6 vs 155 ± 65.5 mmHg, p = 0.02). Compared with controls (167 ± 42.3 mmHg), neither GM1 (p = 0.053) nor GM2 (p = 0.379) differed significantly. Adhesions occurred in all groups, without significant differences. Histological evaluations showed typical granulation tissue and fibrosis, with granulocytic inflammation more common in GM1 without affecting anastomotic stability. Conclusion: This proof-of-concept study demonstrates that the PDO membrane can be safely incorporated into stapled anastomoses without compromising anastomotic healing. The membrane provides a stable, biocompatible platform suitable for future sensor integration, supporting the development of a diagnostic intraanastomotic device.
Reference Key
imported_1768904012_696f554c17cec Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Schafmayer, Clemens
Journal Frontiers in surgery
Year Year not found
DOI
10.3389/fsurg.2026.1746520
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.