Case Report: Application of the LVIS stent as a bridging device for salvage treatment of malapposed lattice flow diverter in a giant posterior circulation aneurysm: technical note and clinical efficacy

Clicks: 2
ID: 309877
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #40 of 490 articles by views in Frontiers in surgery

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 490 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
ObjectiveTo evaluate the feasibility, technical nuances, and clinical outcomes of using the LVIS stent as a bridging device for the salvage treatment of a malapposed Lattice flow diverter (FD) in a giant posterior circulation aneurysm.MethodsWe present a detailed case report of a patient with a giant aneurysm in the V4 segment of the vertebral artery. Following implantation of a Lattice blood flow diverter and coils, immediate post-procedural angiography revealed incomplete opening and malapposition at the proximal segment of the stent, accompanied by delayed distal flow. After unsuccessful attempts to improve wall apposition via microcatheter massage, a salvage strategy was employed by deploying an LVIS stent within the malapposed FD segment. This approach aimed to enhance overall wall apposition and metal coverage to achieve ultimate aneurysm occlusion.ResultsThe salvage procedure was performed successfully. The LVIS stent was accurately deployed within the malapposed segment of the FD. Angiographic assessment after the procedure demonstrated complete wall apposition of the composite stent construct and total occlusion of the aneurysm sac. The patient experienced no new neurological deficits during the perioperative period. Short-term follow-up indicated an excellent clinical outcome, with a modified Rankin Scale score of 0.ConclusionUtilizing the LVIS stent as a bridging salvage strategy is a safe and effective technical option for managing malapposed FDs in complex giant posterior circulation aneurysms. This technique effectively enhances stent wall apposition and structural integrity, potentially promoting intra-aneurysmal thrombosis and eventual occlusion. It provides a valuable clinical approach for managing this challenging complication.
Reference Key
imported_1768900550_696f47c62e518 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Cai, Shuzhou
Journal Frontiers in surgery
Year 2026
DOI
10.3389/fsurg.2025.1732753
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.