Practice Parameters for the Treatment of Snoring and Obstructive Sleep Apnea with Oral Appliances: An Update for 2005
Clicks: 4
ID: 306370
2006
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
0.9
/100
4 views
2 readers
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #112 of 192 articles by views in Sleep & breathing = Schlaf & Atmung
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 192 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
These practice parameters are an update of the previously published recommendations regarding use of oral appliances in the treatment of snoring and Obstructive Sleep Apnea (OSA). Oral appliances (OAs) are indicated for use in patients with mild to moderate OSA who prefer them to continuous positive airway pressure (CPAP) therapy, or who do not respond to, are not appropriate candidates for, or who fail treatment attempts with CPAP. Until there is higher quality evidence to suggest efficacy, CPAP is indicated whenever possible for patients with severe OSA before considering OAs. Oral appliances should be fitted by qualified dental personnel who are trained and experienced in the overall care of oral health, the temporomandibular joint, dental occlusion and associated oral structures. Follow-up polysomnography or an attended cardiorespiratory (Type 3) sleep study is needed to verify efficacy, and may be needed when symptoms of OSA worsen or recur. Patients with OSA who are treated with oral appliances should return for follow-up office visits with the dental specialist at regular intervals to monitor patient adherence, evaluate device deterioration or maladjustment, and to evaluate the health of the oral structures and integrity of the occlusion. Regular follow up is also needed to assess the patient for signs and symptoms of worsening OSA. Research to define patient characteristics more clearly for OA acceptance, success, and adherence is needed.
| Reference Key |
openalex_W2126987431
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Clete A. Kushida, Timothy I. Morgenthaler, Michael R. Littner, Cathy Alessi, Dennis R. Bailey, Jack Coleman, Leah Friedman, Max Hirshkowitz, Sheldon Kapen, Milton Kramer, Teofilo Lee‐Chiong, Judith Owens, Jeffrey Pancer |
| Journal | Sleep & breathing = Schlaf & Atmung |
| Year | 2006 |
| DOI |
10.1093/sleep/29.2.240
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.