Sentinel Lymph Node Biopsy and Axillary Dissection in Breast Cancer: Results in a Large Series
Clicks: 3
ID: 304683
1999
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
0.6
/100
3 views
1 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #331 of 341 articles by views in JNCI Journal of the National Cancer Institute
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 341 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
BACKGROUND: Axillary lymph node dissection is an established component of the surgical treatment of breast cancer, and is an important procedure in cancer staging; however, it is associated with unpleasant side effects. We have investigated a radioactive tracer-guided procedure that facilitates identification, removal, and pathologic examination of the sentinel lymph node (i.e., the lymph node first receiving lymphatic fluid from the area of the breast containing the tumor) to predict the status of the axilla and to assess the safety of foregoing axillary dissection if the sentinel lymph node shows no involvement. METHODS: We injected 5-10 MBq of 99m Tc-labeled colloidal particles of human albumin peritumorally in 376 consecutive patients with breast cancer who were enrolled at the European Institute of Oncology during the period from March 1996 through March 1998. The sentinel lymph node in each case was visualized by lymphoscintigraphy, and its general location was marked on the overlying skin. During breast surgery, the sentinel lymph node was identified for removal by monitoring the acoustic signal from a hand-held gamma ray-detecting probe. Total axillary dissection was then carried out. The pathologic status of the sentinel lymph node was compared with that of the whole axilla. RESULTS: The sentinel lymph node was identified in 371 (98.7%) of the 376 patients and accurately predicted the state of the axilla in 359 (95.5%) of the patients, with 12 false-negative findings (6.7%; 95% confidence interval = 3.5%-11.4%) among a total of 180 patients with positive axillary lymph nodes. CONCLUSIONS: Sentinel lymph node biopsy using a gamma ray-detecting probe allows staging of the axilla with high accuracy in patients with primary breast cancer. A randomized trial is necessary to determine whether axillary dissection may be avoided in those patients with an uninvolved sentinel lymph node.
| Reference Key |
openalex_W2036977094
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Umberto Veronesi, Giovanni Paganelli, Giuseppe Viale, Viviana Galimberti, Alberto Luini, Stefano Zurrida, C. Robertson, Virgilio Sacchini, Paolo Veronesi, Enrico Orvieto, Concetta De Cicco, Mattia Intra, G Tosi, Daniela Scarpa |
| Journal | JNCI Journal of the National Cancer Institute |
| Year | 1999 |
| DOI |
10.1093/jnci/91.4.368
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.