Development of an UPLC-MS/MS method coupled with in-source CID for quantitative analysis of PEG-PLA copolymer and its application to a pharmacokinetic study in rats.
Clicks: 443
ID: 3046
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
81.8
/100
443 views
324 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #2 of 46 articles by views in journal of chromatography b, analytical technologies in the biomedical and life sciences
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Poly(ethylene glycol)-block-poly(lactic acid) (PEG-PLA) is a biocompatible and amphiphilic block copolymer composed of a hydrophilic PEG block and a hydrophobic PLA block, which can self-assemble into micelles in water. It is one of the most commonly used biodegradable polymers for drug encapsulation, drug solubilization and drug delivery. Due to the complexity and heterogeneity of PEG-PLA, the precise analysis of this polymer is a great challenge. This study reports an application of an UPLC tandem mass spectrometry coupled with in-source collision induced dissociation (CID) technique for the analysis of a model compound mPEG2000-PDLLA2500-COOH, which could be dissociated in source and generate a series of fragment ions corresponding to its subunits. These surrogate ions including PLA-specific and PEG-specific fragment ions could be further broken into specific product ions in collision cell. Finally, the ion transition at m/z 505.0 → 217.0 was selected for the quantitation of mPEG2000-PDLLA2500-COOH. This assay achieved a lower limit of quantitation (LLOQ) of 0.05 μg/mL with only 30 μL rat plasma. The linear range is 0.05 to 5 μg/mL. Intraday and interday accuracy and precision were within ±12.1%. The method was successfully applied to the pharmacokinetic study of mPEG2000-PDLLA2500-COOH in rats. The results revealed that LC-MS/MS coupled with in-source CID is a sensitive and specific strategy for analysis of PEG-PLA. This method can be potentially extended to the analysis of other pharmaceutical polymer excipients.
| Reference Key |
shi2019developmentjournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Shi, Meiyun;Jiang, Hui;Yin, Lei;Liu, Yajun;Xu, Mengyao; |
| Journal | journal of chromatography b, analytical technologies in the biomedical and life sciences |
| Year | 2019 |
| DOI |
S1570-0232(19)30686-5
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.