Overriding of Drug Safety Alerts in Computerized Physician Order Entry
Clicks: 1
ID: 298093
2005
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
0.0
/100
1 views
0 readers
AI Quality Assessment
Not analyzed
Readership in this journal
Ranked #65 of 76 articles by views in Journal of the American Medical Informatics Association : JAMIA
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Many computerized physician order entry (CPOE) systems have integrated drug safety alerts. The authors reviewed the literature on physician response to drug safety alerts and interpreted the results using Reason's framework of accident causation. In total, 17 papers met the inclusion criteria. Drug safety alerts are overridden by clinicians in 49% to 96% of cases. Alert overriding may often be justified and adverse drug events due to overridden alerts are not always preventable. A distinction between appropriate and useful alerts should be made. The alerting system may contain error-producing conditions like low specificity, low sensitivity, unclear information content, unnecessary workflow disruptions, and unsafe and inefficient handling. These may result in active failures of the physician, like ignoring alerts, misinterpretation, and incorrect handling. Efforts to improve patient safety by increasing correct handling of drug safety alerts should focus on the error-producing conditions in software and organization. Studies on cognitive processes playing a role in overriding drug safety alerts are lacking.
| Reference Key |
openalex_W2110922423
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | H. van der Sijs, J. Aarts, Arnold G. Vulto, Maarten J. ten Berg |
| Journal | Journal of the American Medical Informatics Association : JAMIA |
| Year | 2005 |
| DOI |
10.1197/jamia.m1809
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.