Abstract
Background and Objectives
The authors report a case of unintentional subdural block in a parturient with prior Harrington rod insertion.Methods
The epidural technique was performed successfully at the L5-S1 interspace using the loss-of-resistance technique after two failed attempts at the L3-4 interspace.Results
Twenty to 30 minutes after total initial dose of 9 mL 0.25% bupivacaine with 1/200,000 epinephrine, the patient developed hypotension and a high sensory block involving the trigeminal nerve. The patient also complained of difficulties in swallowing and breathing. Signs and symptoms strongly suggested an unintentional subdural block. After careful monitoring and reassurance, the patient’s sensory level receded and she could breathe and swallow comfortably. Intubation was not required. The epidural catheter was maintained in the same space. The amount of 0.25% bupivacaine was reduced to 2 mL for subsequent top-ups. Adequate analgesia was provided throughout the course of her labor and delivery without other complications.Conclusions
Lumbar epidural anesthesia is not always an easily performed technique and is known to be associated with a higher incidence of complications in patients with prior Harrington rod insertion. Prompt recognition and proper management of subdurally placed needle and catheter avoided more serious complications.| Reference Key |
openalex_W2318110983
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | |
| Journal | american journal of science |
| Year | 1948 |
| DOI |
10.2475/ajs.246.4.241
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
ZincirX productsfrom the team behind Journament
-
PatentYazar
Patent drafts for the EPO, USPTO and TürkPatent
From inventor notes to a DOCX draft: description, claims, abstract. The machine drafts, the attorney signs.
See how it works (opens in a new tab) -
Projenator
Have a project idea? Score and plan it with AI
AI scores your idea in five dimensions and builds a phased plan. Your first project is free, no card needed.
Start your first project (opens in a new tab)
Cookies
We use strictly necessary cookies to run the site and keep you signed in. With your permission we would also use Google Analytics to see how the site is used, and Google AdSense to show ads on journal and article pages. Both stay off unless you accept, and you can change your mind at any time. How we use cookies · KVKK notice (Türkiye)
Cookie settings
Comments
No comments yet. Be the first to comment on this article.