Notes on Recent brachiopods
Clicks: 3
ID: 298042
1948
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
0.6
/100
3 views
2 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #6,956 of 8,486 articles by views in american journal of science
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 8,486 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Background and Objectives
The authors report a case of unintentional subdural block in a parturient with prior Harrington rod insertion.Methods
The epidural technique was performed successfully at the L5-S1 interspace using the loss-of-resistance technique after two failed attempts at the L3-4 interspace.Results
Twenty to 30 minutes after total initial dose of 9 mL 0.25% bupivacaine with 1/200,000 epinephrine, the patient developed hypotension and a high sensory block involving the trigeminal nerve. The patient also complained of difficulties in swallowing and breathing. Signs and symptoms strongly suggested an unintentional subdural block. After careful monitoring and reassurance, the patient’s sensory level receded and she could breathe and swallow comfortably. Intubation was not required. The epidural catheter was maintained in the same space. The amount of 0.25% bupivacaine was reduced to 2 mL for subsequent top-ups. Adequate analgesia was provided throughout the course of her labor and delivery without other complications.Conclusions
Lumbar epidural anesthesia is not always an easily performed technique and is known to be associated with a higher incidence of complications in patients with prior Harrington rod insertion. Prompt recognition and proper management of subdurally placed needle and catheter avoided more serious complications.| Reference Key |
openalex_W2318110983
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | P. E. Cloud |
| Journal | american journal of science |
| Year | 1948 |
| DOI |
10.2475/ajs.246.4.241
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.