[Application of solid phase extraction disk in the determination of acrylamide in tap water].
Clicks: 345
ID: 2913
2010
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
75.5
/100
345 views
227 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #10 of 69 articles by views in se pu = chinese journal of chromatography
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A simple and fast method of solid phase extraction (SPE) disk for the determination of trace acrylamide was developed. Using this new technique along with high performance liquid chromatography (HPLC) and ultraviolet spectroscopy (UV) detection, the feasibility of SPE disk method for rapid enrichment was demonstrated in the determination of trace acrylamide in 500 mL tap water. Active carbon was chosen as the adsorbent to be incorporated into the SPE disk as it gave the best adsorption efficiency. Experimental parameters including solvent, elution volume, elution rate, breakthrough volume were optimized to give the highest efficiency of extraction. Under proper chromatographic conditions, acrylamide was easily separated from other impurities. A linear relationship between peak area and mass concentration in the range 0.05-0.5 mg/L of acrylamide was established with a correlation coefficient of 0.998. The limit of detection was 20 ng/L. The recoveries for acrylamide with different concentrations and volumes ranged from 94.12% to 100.2%. The relative standard deviations (RSDs) were 2.09%-4.51% (n=3). The recovery for acrylamide spiked into a tap water sample was 79. 96%. The method is simple, fast, sensitive and suitable for the determination of acrylamide in tap water.
| Reference Key |
zhang2010applicationse
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Zhang, Bo;Qi, Yue;Gao, Henan;Bao, James Jianmin; |
| Journal | se pu = chinese journal of chromatography |
| Year | 2010 |
| DOI |
DOI not found
|
| URL | URL not found |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.