Amplification efficiency: linking baseline and bias in the analysis of quantitative PCR data

Clicks: 1
ID: 290158
2009
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal

Ranked #768 of 1,214 articles by views in Nucleic Acids Research

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,214 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Despite the central role of quantitative PCR (qPCR) in the quantification of mRNA transcripts, most analyses of qPCR data are still delegated to the software that comes with the qPCR apparatus. This is especially true for the handling of the fluorescence baseline. This article shows that baseline estimation errors are directly reflected in the observed PCR efficiency values and are thus propagated exponentially in the estimated starting concentrations as well as ‘fold-difference’ results. Because of the unknown origin and kinetics of the baseline fluorescence, the fluorescence values monitored in the initial cycles of the PCR reaction cannot be used to estimate a useful baseline value. An algorithm that estimates the baseline by reconstructing the log-linear phase downward from the early plateau phase of the PCR reaction was developed and shown to lead to very reproducible PCR efficiency values. PCR efficiency values were determined per sample by fitting a regression line to a subset of data points in the log-linear phase. The variability, as well as the bias, in qPCR results was significantly reduced when the mean of these PCR efficiencies per amplicon was used in the calculation of an estimate of the starting concentration per sample.
Reference Key
openalex_W2136309995 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Jan M. Ruijter, Christian Ramakers, Willem M.H. Hoogaars, Yann Karlen, Onno Bakker, Maurice J.B. van den Hoff, Antoon F.M. Moorman
Journal Nucleic Acids Research
Year 2009
DOI
10.1093/nar/gkp045
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.