Assessing bleeding rates, related clinical impact and factor utilization in German hemophilia B patients treated with extended half-life rIX-FP compared to prior drug therapy.

Clicks: 351
ID: 28460
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #7 of 38 articles by views in current medical research and opinion

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
An extended half-life factor IX (FIX) fusion protein linking recombinant FIX with recombinant human albumin (rIX-FP), indicated for the treatment of hemophilia B, was approved by the European Medicines Agency in May 2016. We aimed to compare clinical outcomes and drug utilization in patients who switched from prior FIX therapies to rIX-FP.Anonymized patient chart data were collected from German institutions treating patients with hemophilia B. Patients were included if they had been treated with rIX-FP for ≥8 weeks at the time of data collection. Bleeding rates and FIX consumption were compared between rIX-FP and patients' prior FIX products.Data were obtained for 81 male patients treated with rIX-FP, including 59 who received prophylaxis with both their prior drug and rIX-FP (prophylaxis-to-prophylaxis group). Mean factor consumption in this group was 44.2 IU/kg/wk for rIX-FP compared with 82.3 IU/kg/wk for all prior FIX products. In addition, intra-patient analysis of factor consumption showed lower consumption of rIX-FP compared with prior FIX in 56 of 59 patients. Among the patients for whom bleed data were available (n = 42), annualized bleeding rate decreased from a mean (standard deviation) of 2.6 ± 2.9 on prior product to 0.3 ± 0.6 on rIX-FP. The proportion of patients with zero bleeds increased from 24% with prior therapy to 81% with rIX-FP.rIX-FP was associated with substantial reductions in bleeding rates and consumption of FIX compared with standard half-life products that require more frequent administration.
Reference Key
oldenburg2019assessingcurrent Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Oldenburg, Johannes;Yan, Songkai;Maro, Geraldine;Krishnarajah, Girishanthy;Tiede, Andreas;
Journal current medical research and opinion
Year 2019
DOI
10.1080/03007995.2019.1662675
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.