Application of immobilized ZnO nanoparticles for the photocatalytic regeneration of ultrasound pretreated-granular activated carbon.
Clicks: 266
ID: 27934
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
62.7
/100
266 views
215 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #35 of 59 articles by views in ultrasonics sonochemistry
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
In this study, the photocatalytic regeneration by ZnO was employed for the regeneration of the granular activated carbon (GAC) which was saturated with the reactive red 43. The ultrasound was applied as a pretreatment step due to the cleanup of the adsorbent surface and providing a higher surface area and adsorption capacity. According to the nitrogen gas adsorption-desorption results, the ultrasound pretreated-GAC had the highest surface area and the total pore volume. The SEM and XRD analyses confirmed the immobilization of ZnO nanoparticles on the GAC. Response surface methodology (RSM) was used to model and optimize the preparation of the granular activated carbon/ZnO nanocomposite. The sonication time, pH, GAC/ZnO ratio, and calcination temperature were used as four effective parameters on nanocomposite preparation. Optimum amounts of pH, GAC/ZnO ratio, calcination temperature, and sonication time were found to be equal to 4, 5, 300 °C, 210 min, respectively; in these conditions, 83.98% of the capacity of the exhausted granular activated carbon was regenerated. ANOVA results, high R, R-adj values, and also normal and random distribution of residuals showed that application of RSM for the modeling and optimizing the preparation step of GAC/ZnO nanocomposite was successful.
| Reference Key |
aber2019applicationultrasonics
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Aber, Soheil;Tajdid Khajeh, Rana;Khataee, Alireza; |
| Journal | ultrasonics sonochemistry |
| Year | 2019 |
| DOI |
S1350-4177(19)30124-5
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.