Detection of Acanthamoeba spp. in groundwater sources in a rural area in the Philippines.
Clicks: 148
ID: 278305
2023
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
148 views
28 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #27 of 30 articles by views in Journal of water and health
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Research on free-living amoebae (FLA) and its public health implication as an etiologic agent of parasitic infection in humans has recently gained traction in the Philippines. This study aimed to identify potential FLAs in collected groundwater samples from Masinloc, Zambales, Philippines. Fifty-four (54) water samples were collected in 250-mL sterile polyethylene containers by purposive sampling from selected groundwater sources in six (6) barangays of Masinloc. The samples were vacuum filtered through a 1.2-μm pore glass microfiber filter, cultured onto non-nutrient agar (NNA) lawned with Escherichia coli, and observed microscopically for amoebic growth for 14 days using light microscopy. Amoebic growth was observed in 11.1% (6/54) of water samples. DNAs from positive samples were extracted and were made to react with polymerase chain reaction using Acanthamoeba-specific JDP1 (5'-GGCCCAGATCGTTTACCGTGAA-3') and JDP2 (5'-TCTCACAAGCTGCTAGGGAGTCA-3') primers, and universal primer Euk A (5'-AACCTGGTTGATCCTGCCAGT-3') and Euk B (5'-TGATCCTTCTGCAGGTTCACCTAC-3'). The presence of Acanthamoeba genotypes T4, T7, and T11 was confirmed using molecular and phylogenetic analysis. Our results confirmed that groundwater sources from two of six sampling sites (33.3%) in Masinloc, Zambales, were contaminated with potentially pathogenic FLAs. Proper identification of risk factors that may cause contamination consequently leads to the implementation of programs that will prevent future infections.
| Reference Key |
padua2023detectionjournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Padua, Mark F F E;Masangkay, Frederick Ramirez;Alejandro, Grecebio Jonathan D;Milanez, Giovanni De Jesus; |
| Journal | Journal of water and health |
| Year | 2023 |
| DOI |
10.2166/wh.2023.258
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.