Serum endocan level and diastolic functions in the case of lead exposure

Clicks: 336
ID: 274825
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #7 of 33 articles by views in Turkish journal of medical sciences

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Lead can cause morphological and functional changes in heart, and inflammation and endothelial dysfunction in vasculature. Endocan, as a novel indicator of endothelial dysfunction, has been used for cardiovascular diseases. This study investigated the relationship between lead exposure, endocan levels, and diastolic functions.A total of 51 lead-exposed workers without a known cardiovascular disease or risk factors and 54 healthy controls were enrolled. All participants underwent transthoracic echocardiography. Blood lead and serum endocan levels were analyzed.Baseline demographic and clinical characteristics were found to be similar between groups. Median blood lead (32 vs 1.5 μg/dL, P < 0.001) and serum endocan levels (67 vs 57.1 pg/mL, P = 0.02) were significantly higher in the lead-exposed group. Serum endocan level showed a positive correlation with blood lead levels (r = 0.404, P = 0.003) in lead-exposed workers. Serum endocan level was an independent risk factor for increased E/E’ ratio (β = 0.704, P = 0.002) and left atrial volume index (β = 1.158, P = 0.011) and higher level of lead in blood was an independent risk factor for increased E wave (β = 8.004, P = 0.022) in lead-exposed workers.Worsened diastolic functions may be seen in the course of lead exposure. Due to sharing a similar mechanism, a higher serum level of endocan may be a valuable laboratory clue for impaired diastolic function in this population.
Reference Key
kara2019serumturkish Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Kara, Halil;Karakulak, Uğur Nadir;Gündüzöz, Meside;Bal, Ceylan;Alışık, Murat;Büyükşekerci, Murat;İritaş, Servet Bilgin;Yılmaz, Ömer Hınç;Tutkun, Lütfiye;
Journal Turkish journal of medical sciences
Year 2019
DOI
10.3906/sag-1801-146
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.