Fracture resistance of cantilevered full-arch implant-supported hybrid prostheses with carbon fiber frameworks after thermal cycling.
Clicks: 235
ID: 274796
2021
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
235 views
34 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #12 of 19 articles by views in Journal of dentistry
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
This in vitro study aimed to find the best combination of mesostructure and veneering materials for full-arch implant-supported hybrid prostheses (HPs) in terms of the fracture resistance (FR) of their cantilevers.Three groups (n= 5 each) of maxillary HPs were fabricated: Group-1 (CC-A, control): Co-Cr frameworks coated with acrylic resin; Group-2 (CF-A): carbon fiber veneered with acrylic resin; and Group-3 (CF-R): carbon fiber coated with composite resin. All specimens were submitted to 5,000 thermal cycles (5 °C - 55 °C, dwell time: 30 s), and subjected to a single cantilever bending test in a universal testing machine (crosshead speed: 0.5 mm/min) until failure. The fracture pattern was assessed using stereo microscope and SEM. The one-way ANOVA and Bonferroni tests were run (α= 0.05).The FR yielded significant differences among the three groups (p< 0.001). CC-A samples reached the highest FR values (p≤ 0.001), whereas both CF-A and CF-R HPs exhibited the comparably (p= 0.107) lowest FR. CC-A specimens failed cohesively (100%): mostly without chipping (80%). CF-A mesostructures were always broken at the connections of the distal implants. CF-R prostheses often failed adhesively (80%).The HPs made of Co-Cr veneered with acrylic demonstrated the best mechanical behaviour, being the only group whose 13-mm long cantilevers exceeded the clinically acceptable FR of 900 N. The HPs constructed with carbon fiber frameworks showed, additionally, more unfavourable fracture patterns.For HPs with cantilevers up to 13 mm, Co-Cr mesostructures coated with acrylic may represent the optimum combination of materials.
| Reference Key |
haroyandarbinyan2021fracturejournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Haroyan-Darbinyan, Evelina;Romeo-Rubio, Marta;Río-Highsmith, Jaime Del;Lynch, Christopher D;Castillo-Oyagüe, Raquel; |
| Journal | Journal of dentistry |
| Year | 2021 |
| DOI |
S0300-5712(21)00324-9
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.