Performances of the beam monitoring system and quality assurance equipment for the HIMM of carbon-ion therapy.
Clicks: 232
ID: 261313
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
232 views
53 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #14 of 18 articles by views in Journal of applied clinical medical physics
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The heavy-ion medical machine (HIMM), which is the first commercial medical accelerator designed and built independently by the institute of modern physics (IMP) in Wuwei, Gansu Province, China, had officially completed clinical trials at the time of this article's writing. Three types of detector systems were developed based on the ionization-chamber principle to monitor the beam parameters during treatment in real time, quickly verify the beam performance during a routine checkup, and ensure patient safety.The above-mentioned detector systems were used for beam monitoring and quality assurance in the treatment system. The beam-monitoring system is composed of three integral ionization chambers (ICs) and two multistrip ionization chambers (MSICs) as a redundant design. The irradiation dose, beam position, and homogeneity of a lateral profile are monitored online by the beam-monitoring system, and safety interlocks are established to keep the test results under the predefined tolerance limitation. The quality-assurance equipment was composed of one MSIC and one IC stack. The IC stack was used for energy verification.The off-axis response of ICs is within a tolerance of 2%, and the dose interlock system (DIS) response time is less than 7 ms during the treatment process. The positioning resolution of MSICs reached 73 µm. The IC stack can verify the beam range within one spill and the measurement resolution is less than 0.2 mm.The beam-monitoring system (BMS) and quality-assurance equipment (QAE) have been installed and run successfully within HIMM for two years and are associated with the HIMM treatment system to deliver the right dose to the correct position precisely. Furthermore, the daily QA task is simplified by it. Above all, the system has passed the performance test of the China Food and Drug Administration (CFDA).
| Reference Key |
wei2020performancesjournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Wei, Kun;Xu, Zhiguo;Mao, Ruishi;Zhao, Zulong;Zhao, Tiecheng;She, Qianshun;Kang, Xincai;Wang, Jianli;Li, Shengpeng;Li, Min;Song, Kai;Yang, Herun;Duan, Limin; |
| Journal | Journal of applied clinical medical physics |
| Year | 2020 |
| DOI |
10.1002/acm2.12916
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.