autotransfusão intra-operatória em cirurgia cardíaca: estudo comparativo de 140 casos intraoperative autotransfusion in heart surgery: comparative study of 140 cases

Clicks: 138
ID: 259941
1992
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #75 of 103 articles by views in 2017 international conference on information technology systems and innovation, icitsi 2017 - proceedings

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Utilizando-se programa dirigido para diminuição ou eliminação do uso de sangue homólogo, em pacientes cirúrgicos graves, foi realizado um estudo comparativo entre 14 0 casos. Os pacientes foram divididos em 2 grupos de 70 casos cada, onde o Grupo A representava aqueles submetidos a cirurgia cardíaca com o uso de recuperadores celulares automatizados de sangue cell-saver, no Grupo B, os pacientes que não utilizaram cell-saver durante o ato cirúrgico (Grupo controle). A maioria era de reoperações: 71,1 % no Grupo A e 74,2 % no Grupo B, observando-se, ainda, semelhança entre os respectivos grupos em relação a: idade, distribuição por sexo, tipo de operação, condições clínicas e aspectos laboratoriais pré-operatórios (coagulograma; eritrograma; série bioquímica). No Grupo A a utilização média de sangue homólogo, durante o ato cirúrgico, foi de 628 ml, e 479 ml no pós-operatório imediato. Já no Grupo B o uso de sangue homólogo foi de 1.271 ml e 1.095 ml, respectivamente. A perda sangüínea média na sala cirúrgica do Grupo A foi de 380 ml, enquanto que a do Grupo B foi de 89 9 ml. O número de pacientes do Grupo A que não necessitou de sangue homólogo durante o período de internação foi o dobro (5,7%) em relação ao Grupo B (2,8%). A maioria dos pacientes do Grupo A (51,4%) utilizou no máximo 2 unidades de sangue homólogo, enquanto que a maioria dos paciientes do Grupo B (78,6%) utilizou entre 3 ou mais de 5 unidades de sangue homólogo. O estudo mostra, portanto, que a utilização da autotransfusão intra-operatória (ATI) através de processadores celulares automatizados (cell-saver) em cirurgia cardíaca é um procedimento seguro e eficaz, reduzindo em aproximadamente 50 % a utilização de sangue homólogo, com as possíveis reações transfusionais e, principalmente, o risco da transmissão de doenças infecto-contagiosas.
An intraoperative autotransfusion was planned in order to decrease or to avoid transfusion of blood in severe surgical cases. It was done a comparative study in 14 0 heart surgeries; 70 cases (Group A) were submitted to heart surgery making use of Cell-Saver and 70 without the use of it. The majority of the cases have had a previous surgery; 77.1 % of the cases in Group A and 74.2 % in Group B. Besides this similarity other likeness included age, sex, kind of surgery, clinical conditions and laboratory data concerning coagulation, erythrocyte count and blood biochemistry. The averaged homologous blood volume intraoperative transfused was 628 ml in Group A and 1271 ml in Group B, but it was 479 ml in Group A and 1095 ml in Group B after surgery. The intraoperative blood lost was 38 0 ml in Group B. During the hospitalization time the percentage of cases that did not receive blood was 5.7 % in Group A and 2,8 % in Group B. The average amount of units transfused was 2 in Group A and 3 ro 5 or higher in Group B. The study pointed out that intraoperative autologous transfusion using Cell Saver is a safety and efficient procedure. The transfusion of homologous blood decreased in 50 % as well as the risk of infection disease to be transmited.
Reference Key
vieira1992brazilianautotransfuso Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Sérgio Domingos Vieira;Marielza dos Santos;Thucydides Rosales;Luiz Carlos Bento de Souza;Jarbas J Dinkhuysen;Paulo Chaccur;Camilo Abdulmassih Neto;Ricardo Pavanello;Adib D Jatene
Journal 2017 international conference on information technology systems and innovation, icitsi 2017 - proceedings
Year 1992
DOI
DOI not found
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.