peculiarities of biomechanical properties of ocular tissue in keratoconus
Clicks: 250
ID: 259821
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
30.0
/100
250 views
36 readers
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #9 of 11 articles by views in clinical and translational medicine
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Considerable achievements having been recently made in modern diagnostics and treatment of keratoconus have not diminished the urgency of the given problem as the traditional views of the pathogenesis of keratoconus do not always allow to struggle effectively with this difficult and continuously progressing disease.
The objective of the research was to study the peculiarities of biomechanical properties of the cornea in keratoconus.
Materials and methods. The article presents the analysis of studying biomechanical properties of the cornea in keratoconus. 44 patients (88 eyes) with keratoconus and emmetropic refraction were examined. To calculate biomechanical indicators of the cornea there was carried out the comparative analysis between the measurements obtained with the use of several methods in the same patients, namely the Oculus Pentacam-Scheimpflug imaging device by a standard technique and the indicators calculated using the method proposed by us and the device for in vivo estimation of corneal rigidity.
Results. Considerable advantages of using the developed method and the device for estimation of corneal rigidity in vivo in comparison with keratotopography on the Oculus Pentacam-Scheimpflug camera were registered which allowed us not only to reveal the presence of biomechanical disorders of the cornea, but also to differentiate their character. To describe the degree of changes in biomechanical properties of the cornea in vivo the coefficient of corneal rigidity was developed.
Conclusions. Loading tests allow receiving more exact information on biomechanical properties of the cornea in comparison with standard researches on the Oculus Pentacam-Scheimpflug camera.
| Reference Key |
shargorodska2016galicianpeculiarities
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Iryna Shargorodska |
| Journal | clinical and translational medicine |
| Year | 2016 |
| DOI |
10.21802/gmj.2016.4.21
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.