study of the properties of drinking water for kirkuk city and its pollution in some areas
Clicks: 2
ID: 259160
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
0.3
/100
2 views
1 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #435 of 435 articles by views in acta botânica brasílica
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 435 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
This study was conducted to demonstrate the difference between drinking water quality for seven different areas of Kirkuk city with the treatment water in the main and three sub storages tanks, affected with drinking water pipe lines, supplying system Alternate and continuous and also pipes across the construction work’s areas. The physical and chemical properties (turbidity, pH, conductivity, Alkalinity, Total hardness, calcium, magnesium, chloride, sulfate, TDS (Total dissolve solids), TSS (Total suspended solids), sodium and potassium) for raw water and treated water in the Storages in addition to the supplying water from seven different areas in Kirkuk were analyzed, samples taken at a rate nine times during the month of March. Results showed that Drinking water of Dumez, Wasti, Shorja, Imam Qasim and Arubaa polluted with turbidity with an average levels of (8.68, 6.04, 7.41, 6.95, 7.64) NTU respectively, over the limit allowed by IBWA (International Bottled Water Association), 2012 and WHO (World Health Organization), 2006. The turbidity in the main and sub storages have reached (4.04, 4.09, 4.47, 4.16) NTU respectively, while other physical and chemical properties were within the allowed limits for human use. The pollution in those areas caused by the alternative supplying system of treatment water and it has negative impact on the pipelines, it includes constriction work in areas also where pipelines exist.
| Reference Key |
hussein2018matecstudy
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Zainulabdeen Iman Hussein |
| Journal | acta botânica brasílica |
| Year | 2018 |
| DOI |
10.1051/matecconf/201816205008
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.