assessment of variation in depth of brachial plexus using ultrasound for supraclavicular brachial plexus block in patients undergoing elective upper limb surgery

Clicks: 462
ID: 258466
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #2 of 138 articles by views in Veterinary radiology & ultrasound : the official journal of the American College of Veterinary Radiology and the International Veterinary Radiology Association

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 138 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Background and Aims: Supraclavicular approach to the brachial plexus may be associated with complications such as pneumothorax, inadvertent vascular puncture, inter-scalene block and neurovascular injuries. The present study was conceived to find out the variation in depth of brachial plexus to suggest the minimum length of needle required to effectively perform the block, thus preventing possible complications. Methods: After approval from our Institutional Ethical Committee, informed and written consent was obtained from each of the ninety American Society of Anesthesiologists Physical Status I and II patients recruited, of either sex in the age group of 20–50 years. Supraclavicular fossa was scanned using a high-frequency linear probe, and the distances (shortest distance [SD] from skin to the most superficial neural element and longest distance [LD] from skin to the most deep neural element) were measured using on-screen callipers on optimal frozen image. Pearson correlation was used to find out the relation between these two distances and demographic parameters. Results: Mean SD was 0.60 ± 0.262 cm, and mean LD was found to be 1.34 ± 0.385 cm. We observed significant correlation between these two distances with weight and body mass index (BMI). Conclusion: Significant correlation was observed between SD and LD with weight and BMI. We suggest that a needle with a shaft length of 3 cm will be sufficient to reach the sheath of the brachial plexus during performance of the block.
Reference Key
mistry2016indianassessment Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Tuhin Mistry;Vandana Mangal;Gaurav Sharma;Aachu Agrawal
Journal Veterinary radiology & ultrasound : the official journal of the American College of Veterinary Radiology and the International Veterinary Radiology Association
Year 2016
DOI
10.4103/0019-5049.183385
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.