Can locking plate fixation of symphyseal disruptions allow early weight bearing?
Clicks: 116
ID: 258345
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
116 views
15 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #24 of 26 articles by views in Injury
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Anterior pubic symphyseal plate fixation is the recommended treatment for disruption of pubic symphysis in an unstable pelvic ring injury. The rigid construct offered by locking symphyseal plate has the theoretical advantage of allowing patients to weight bear early. However, there are concerns of catastrophic failure about the locked plate construct. The purpose of the study was to establish if locking plate fixation for pubic symphysis disruption was effective to allow patients to mobilise weight bearing immediately after surgery.Retrospective analysis of a prospectively collected database from a single centre was performed. The study period was from 2008 to 2017. Radiographic evidence of fixation failure, revision surgery, removal of metalwork and follow up duration was noted.We identified 46 patients (F:M 8:38) with a mean age of 46 years (range 14 to 74 years). Based on the mechanism of injury patients were classified into Antero-posterior compression (28), Vertical shear [10], lateral compression [4] and combined mechanism [4]. Either a 4-hole or 6-hole locking plate was used in all patients, depending on fracture extension. Posterior fixation was required in 28 (61%) patients. All patients were allowed to fully or partial weight bear. The mean radiological follow-up period was 31 weeks with 13 (28%) patients having evidence of radiological failure. Revision was performed in 1 (2%) patient, in whom the screws had pulled out of the bone. The most common mode of failure was either the screw backing out from the plate or broken screw. Among the 4 (8%) patients who had their metalwork removed, 1 (2%) had delayed onset of infection, 2 (4%) had symptoms related to backed out screw and 1 (2%) opted electively to have metalwork removed.With our series of patients, we have found that using locking plate for pubic symphyseal diastasis is safe and effective in allowing patients to weight bear early. A low complication rate and need for re-operation is demonstrated.
| Reference Key |
kankanalu2020caninjury
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Kankanalu, Pradeep;Orfanos, Georgios;Dwyer, Jonathan;Lim, Justin;Youssef, Bishoy; |
| Journal | Injury |
| Year | 2020 |
| DOI |
S0020-1383(20)30169-8
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.