heat transfer enhancement in tubular heat exchanger with double v-ribbed twisted-tapes
Clicks: 285
ID: 258053
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
285 views
35 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #6 of 16 articles by views in gateways : international journal of community research & engagement
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
An experimental work on heat transfer enhancement in a round tube by insertion of double twisted tapes in common with 30° V-shaped ribs has been conducted. Air as the test fluid flowed through the test tube having a constant wall heat-flux with Reynolds number (Re) from 5300 to 24,000. The combined vortex generators (called “V-ribbed twisted tape”) were obtained by incorporating V-shaped ribs into the edges of double co-twisted tapes having a similar twist ratio of 4. The effect of pertinent V-rib parameters such as four relative rib heights, (called “blockage ratio”, BR=b/D= 0.07, 0.09, 0.14 and 0.19) and a relative rib pitch, (PR=P/D=1.9) at an attack angle of rib, α=30° on thermal characteristics was investigated. The experimental results reveal that the heat transfer and pressure drop in terms of the respective Nusselt number and friction factor for the V-ribbed twisted tapes show the increasing trend with the rise of Re and BR. The V-ribbed twisted tape with BR=0.19 yields the highest heat transfer and friction factor. However, the maximum thermal enhancement factor is about 1.4 for the V-ribbed twisted tape at BR=0.09 but is around 1.09 for the twisted tape with no rib.
| Reference Key |
tamna2016caseheat
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Sombat Tamna;Yingyong Kaewkohkiat;Sompol Skullong;Pongjet Promvonge |
| Journal | gateways : international journal of community research & engagement |
| Year | 2016 |
| DOI |