correlation between two chemiluminescence based assays for quantification of hepatitis b surface antigen in patients with chronic hepatitis b infection

Clicks: 462
ID: 257771
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #2 of 129 articles by views in bjog : an international journal of obstetrics and gynaecology

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 129 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Purpose: Hepatitis B surface Antigen (HBsAg) is the hallmark in diagnosing hepatitis B virus (HBV) infection. In India many commercial assays are available for detection of HBsAg but very few can measure it quantitatively. The present study presents the comparative evaluation of two methods and their correlation with serum HBsAg in chronic hepatitis B (CHB) patients. Materials and Methods: Consecutive patients of CHB were included and there HBsAg levels were measured by two methods: (i) Elecsys, Roche Diagnostics, a qualitative assay and (ii) Architect, Abbott Diagnostics, a quantitative assay. The HBV DNA was measured by real-time polymerase chain reaction (qPCR). Results: Total of 136 patients were included in the study and there was a significant overall correlation between both the assays (correlation coefficient [r] = 0.83; P < 0.001). Assays correlated well with each other across all subgroups of CHB: treatment naοve (r = 0.73; P < 0.001, n = 32), on treatment (r = 0.56; P < 0.05, n = 104), hepatitis Be (HBe) antigen positive (r = 0.67; P < 0.001, n = 62) and anti-HBe positive (r = 0.61; P < 0.05, n = 74) group. On correlation with serum HBV DNA, Architect assay demonstrated good correlation (r = 0.73; P < 0.001, n = 136) as compared to the Elecsys assay (r = 0.27; P = 0.068, n = 136). Architect HBsAg QT assay (A1) also correlated well with HBV DNA in the treatment naοve group (r = 0.69; P < 0.001, n = 32). Conclusions: Our study hence proved that both the assays are comparable and a simple qualitative assay with in-house modification can be used easily for quatitation of HBsAg in clinical samples.
Reference Key
gupta2015indiancorrelation Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;E Gupta;P Pandey;A Kumar;M K Sharma;S K Sarin
Journal bjog : an international journal of obstetrics and gynaecology
Year 2015
DOI
10.4103/0255-0857.148400
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.