Portable Agrichemical Detection System for Enhancing the Safety of Agricultural Products Using Aggregation of Gold Nanoparticles.

Clicks: 195
ID: 25687
2017
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #372 of 475 articles by views in ACS omega

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 475 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Organophosphorus (OP) and triazole chemicals have been commonly used as insecticides and fungicides to protect agricultural foods from harmful insects and fungi. However, these agrichemicals sometimes remain after distribution and can cause serious health and environmental issues. Therefore, it is essential to detect OPs and triazole chemicals in agricultural products. Nowadays, many detection techniques for OPs and triazole chemicals are expensive and time-consuming and require highly trained technicians. Thus, particularly rapid, simple, and sensitive detection methods are in demand for on-site screening of agrichemicals. Gold nanoparticles (AuNPs) have been utilized for applications in analytical assays and real-time monitoring in the biosensor field because of their biocompatibility and outstanding size-dependent optical properties. In this study, we used AuNPs as a detection probe, which have a size of 17 nm in diameter, a red color, and the absorbance peak at 520 nm. When imidazole was added to AuNPs mixed with the agrichemicals, the AuNPs aggregated and their colors changed to purple, causing the appearance of a new peak at 660-670 nm, which could be measured within approximately 20 s. Moreover, we developed a novel device for multiple agrichemical detections using an AuNP-aggregation-based spectrometric detection system. This portable device is light, simple, fast, and highly sensitive as well as selective. With this system, agrichemical residues can be easily detected on the spot at a low cost and in a short reaction time.
Reference Key
baek2017portableacs Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Baek, Seung Hoon;Lee, Seung Woo;Kim, Eun Ju;Shin, Dong-Hyuk;Lee, Seog-Won;Park, Tae Jung;
Journal ACS omega
Year 2017
DOI
10.1021/acsomega.6b00477
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.