análise da qualidade das córneas doadas e do intervalo entre óbito, enucleação e preservação após a implantação de novas normas técnicas e sanitárias em banco de olhos universitário comparative analysis of the donor cornea quality and of the interval between death and preservation before and after new sanitary and technique rules in a university eye bank

Clicks: 207
ID: 250857
2012
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #79 of 137 articles by views in introducing innodb cluster: learning the mysql high availability stack

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 137 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
OBJETIVO: Comparar o intervalo entre o óbito e a enucleação (ΔT-O-E), entre a enucleação e a preservação (ΔT-E-P) e a qualidade da córnea antes e após a implantação de novas normas técnicas e sanitárias baseadas na Resolução RDC 347. MÉTODOS: Estudo retrospectivo em que foram avaliados os prontuários dos doadores de córnea do Banco de Tecidos Oculares da Santa Casa de São Paulo, 2 anos antes e 2 anos depois da implementação de novas normas sanitárias. RESULTADOS: Foi observado aumento do número absoluto de 205 para 374 doadores após as mudanças adotadas. Não foi observada diferença estatisticamente significante no Δt-O-E e ΔT-E-P antes e após as mudanças implantadas. Do total de 1.105 córneas doadas, foi observado 388 córneas doadas antes das mudanças e 717 córneas doadas após as mudanças implementadas. Foi observado aumento estatisticamente significante da graduação da qualidade da córnea doada de 1,76 ± 0,90 para 1,94 ± 0,88 após a implementação das novas normas da Resolução. CONCLUSÃO: Após as mudanças técnicas e sanitárias exigidas pela Resolução 347, houve grande aumento no número de córneas doadas, captadas e preservadas. O Banco de Tecidos Oculares não diminuiu os ΔT O-E e ΔT E-P. A qualidade da córnea apresentou-se inferior após as mudanças realizadas no setor.
PURPOSE: To compare the interval between death and enucleation (ΔT-O-E), between enucleation and preservation (ΔT-E-P) and the quality of the cornea before and after the implantation of new technique and sanitary rules. METHODS: A retrospective study that evaluated the records of cornea donors in Sao Paulo's Santa Casa Eye Tissue Bank 2 years before and 2 years after the implementation new sanitary rules. RESULTS: An increase was observed in the absolute number of 205 to 374 donors following the adopted changes. There was no statistically significant difference in Δt-O-E and ΔT-E-P before and after the implemented changes. Of the total of 1,105 donor corneas, 388 donor corneas were observed before the changes and 717 donor corneas after the implemented changes. We observed a statistically significant increase in grading of donor cornea quality from 1.76 ± 0.90 to 1.94 ± 0.88 after the implementation of new standards of resolution. CONCLUSION: After the changes required by Resolution 347, there was a large increase in the number of donated, taken and preserved corneas. The BTO has not diminished the ΔT O-E and ΔT E-P. Cornea quality presented itself lower after the new rules.
Reference Key
zantut2012arquivosanlise Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Fabio Zantut;Ricardo Holzchuh;Reginaldo Carlos Boni;Eva Cristina Mackus;Paulo Roberto Zantut;Claudio Nakano;Adamo Lui Netto;Richard Yudi Hida
Journal introducing innodb cluster: learning the mysql high availability stack
Year 2012
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.