optimum pump pulse duration for x-ray ar-plasma lasing
Clicks: 101
ID: 249867
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
101 views
42 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #54 of 55 articles by views in pakistan journal of medical sciences
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
In plasma-driven X-ray lasers, it is critical to optimize the duration and time delay between pump pulses. In this study, we have done parametric simulations in order to systematically investigate the optimum time configuration of pump pulses. Here, we are mainly interested in soft X-ray lasers created using a Ar target irradiated with laser pulses, which operate at a wavelength \(\lambda=46.9\) nm in the \(2p^5 3p^1(J=0)\rightarrow 2p^5 3s^1(J=1)\) laser transition. It is shown that the optimum time scale required to achieve Ne-like ions, as well as the time required to generate a population inversion depend on the combined effect of the electron temperature and electron density. The electron density and temperature are respectively a factor of \(\approx\)\(2.1\)- and \(\approx\)\(5\)-times higher in the case of a short pulse of \(0.1\) ps in comparison to a long pulse of 1,000 ps (at a constant fluence). The most effective lasing happens with short pulses with a pulse duration comparable to the total relaxation time from the upper level, namely \(\Delta\tau_p\leq35\) ps. Power laws to predict the optimum laser intensity to achieve Ne-like \(Ar^{+8}\) are obtained.
| Reference Key |
masoudnia2015photonicsoptimum
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Leili Masoudnia;Davide Bleiner |
| Journal | pakistan journal of medical sciences |
| Year | 2015 |
| DOI |
10.3390/photonics2010164
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.