polynuclear nickel hexacyanoferrate/graphitized mesoporous carbon hybrid chemically modified electrode for selective hydrazine detection

Clicks: 191
ID: 249669
2011
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #17 of 36 articles by views in BMJ open quality

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
A hybrid polynuclear nickel hexacyanoferrate (NiHCFe)/graphitized mesoporous carbon- (GMC-) modified glassy carbon electrode (GCE/NiHCFe@GMC) has been prepared by a sequential method using electrodeposited Ni on a GMC-modified glassy carbon electrode (GCE/Ni@GMC) as a template and [Fe(CN)6]3− as an in-situ chemical precipitant, without any additional interlinking agent. Physicochemical and electrochemical characterizations reveal the presence of NiHCFe units within the porous sites of the GMC. The GCE/NiHCFe@GMC electrode showed highly stable and well-defined redox behaviors with surface-confined electron-transfer mechanism in a pH 7 phosphate buffer solution. The GCE/NiHCFe@GMC showed about 20 times enhancement in hydrazine oxidation peak current along with 500 mV reduction in overpotential over the corresponding unmodified GCE/GMC. Hydrazine calibration plots by CV and amperometric i-t methods were linear up to 1 mM and 220 μM with current sensitivity values of 15.86 μA/mM and 7.37 nA/μM, respectively. Calculated detection limit by the amperometric i-t method was 23.2 nM. The hybrid GCE/NiHCFe@GMC exhibits remarkable tolerance to important industrial and biological interferents. Finally determination of hydrazine in cigarette smoke sample was successfully demonstrated.
Reference Key
barathi2011internationalpolynuclear Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Palani Barathi;Annamalai Senthil Kumar;Minnal Ranjan Babu Karthick
Journal BMJ open quality
Year 2011
DOI
10.4061/2011/386023
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.