solubility evaluation of some sealrs used in endodontic treatment, an in-vitro study

Clicks: 109
ID: 248704
2010
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #50 of 54 articles by views in american journal of alzheimer's disease and other dementias

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
"nBackground and Aims: Insolubility has been stated as one of the important characteristics of the materials which are used as sealers in the endodontic treatments. The aim of this study was to evaluate the solubility of four endodontic sealers (ZOE, Dorifill, AH26 and Tubliseal). "nMaterials and Methods: Five specimens from each sealer with similar size were prepared. After first weighing, the samples were stored individually in bottles containing 50 ml of distilled water at 37ºC. After 7 days, the specimens weighed and changes in the weight of each sample recorded with a digital scale. The data were analyzed by ANOVA and Post-hoc Tukey HSD tests. "nResults: The results of this study indicated that Dorifill had the maximum solubility among all sealers with weight loss of 2.8%. Tubliseal and ZOE showed the weight loss of 1.4% and 2.3%, respectively. AH26 showed weight gain of 1.9% during 7 days. There were no significant differences in the mean weight changes between Dorifill, Tubliseal and ZOE groups (P>0.05). A significant difference was found between the mean weight changes of AH26 and that of the other groups (P=0.000). "nConclusion: From the results of this study, all tested sealers were in the standard limit of solubility, and thus, it could confirm this physical property of sealers for clinical applications.
Reference Key
z2010journalsolubility Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Shekaramiz Z;Tabrizizadeh M;Danesh Ardakani M
Journal american journal of alzheimer's disease and other dementias
Year 2010
DOI
DOI not found
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.