in vitro evaluation of the long-term bond strength of two resin cements to enamel and dentin

Clicks: 184
ID: 248552
2014
Free PDF
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #43 of 54 articles by views in american journal of alzheimer's disease and other dementias

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
  Background and Aims : In this in vitro study, the long-term bond strength of a self-adhesive resin cement and conventional resin cements to human enamel and dentin was compared .   Materials and Methods: 80 sections of intact human third molars were randomly assigned into eight groups according to the cement type [Rely X Unicem (RXU), Rely X ARC (RXA)], bond substrate (enamel, dentin) and the duration of water storage (24 h or 1 year). Rods of cements (0.75×1 mm) were prepared on the top surface of specimens using Tygon tubes. The micro-shear bond strengths of specimens were measured by a micro-tensile tester. Data were analyzed using Wilcoxon signed ranks and Mann Whitney tests ( α =0.05).   Results: The bond strengths of RXA and RXU cements to enamel after 24h were 18.56±4.08 MPa and 14.99±4.17 MPa, and after 1 year were 19.41±6.24 MPa and 15.51±6.17 MPa, respectively. The bond strengths of RXA and RXU cements to dentin were 13.36±4.02 MPa and 14.16±4.69 MPa after 24h , and 14.63±5.96 MPa and 14.08±6.72 MPa after 1 year, respectively. Tooth substrate had significant effect only on the shear bond strength of RXA cement after 24h (P=0.01), while no other significant differences were found in this study (P>0.05).   Conclusion: According to the results of this study, one-step self-adhesive and multi-step conventional resin cements were similarly effective in bonding to enamel and dentin after 1 year water storage.
Reference Key
ansari2014journalin Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal american journal of alzheimer's disease and other dementias
Year 2014
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.