evaluation of white matter in patients with multiple sclerosis through diffusion tensor magnetic resonance imaging avaliação da substância branca em pacientes com esclerose múltipla através de ressonância magnética com imagens por tensor de difusão
Article Quality & Performance Metrics
Readership in this journal
SteadyRanked #159 of 475 articles by views in communications in computer and information science
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 475 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
Abstract
OBJETIVO: Estudar a substância branca de pacientes com esclerose múltipla (EM) através de imagens de ressonância magnética (RM) por tensor de difusão (DTI). MÉTODO: Foram avaliados 40 pacientes com diagnóstico clínico-laboratorial de EM remitente-recorrente e quarenta controles pareados por idade e sexo, os quais foram submetidos à RM convencional e funcional (DTI). As seqüências de DTI resultaram em mapas de anisotropia fracionada (FA) e as regiões de interesse foram posicionadas nas placas, regiões peri-placas, substância branca aparentemente normal (SBAN) ao redor das placas, substância branca normal contra-lateral (SBNC) e substância branca normal do grupo controle (SBC). Os valores de FA foram comparados e a análise estatística foi realizada utilizando o teste Mann-Whitney U. RESULTADOS: A média de FA nas placas foi 0,268, nas regiões peri-placas 0,365, na SBAN 0,509, na SBNC 0,552 e na SBC 0,573. Foram observadas diferenças estatisticamente significativas nos valores de FA nas placas, regiões peri-placas e na SBAN ao redor das placas quando comparados com a SBC. Não houve diferença entre os valores de FA na SBNC dos pacientes com EM e na SBC. CONCLUSÃO: Pacientes com EM demonstram diferença nos valores de FA nas placas, peri-placas e SBAN ao redor das placas quando comparados com a SBC. Assim, o DTI pode ser considerado mais eficiente do que as seqüências de ressonância magnética convencional no estudo dos pacientes com EM.
| Reference Key |
andrade2007arquivosevaluation
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Rachel E. Maia de Andrade;Emerson L. Gasparetto;Luiz Celso Hygino Cruz Jr.;Fabiana Brito Ferreira;Roberto Cortês Domingues;Edson Marchiori;Romeu Cortês Domingues |
| Journal | communications in computer and information science |
| Year | 2007 |
| DOI |
10.1590/S0004-282X2007000400002
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
ZincirX productsfrom the team behind Journament
-
PatentYazar
Patent drafts for the EPO, USPTO and TürkPatent
From inventor notes to a DOCX draft: description, claims, abstract. The machine drafts, the attorney signs.
See how it works (opens in a new tab) -
Projenator
Have a project idea? Score and plan it with AI
AI scores your idea in five dimensions and builds a phased plan. Your first project is free, no card needed.
Start your first project (opens in a new tab)
Cookies
We use strictly necessary cookies to run the site and keep you signed in. With your permission we would also use Google Analytics to see how the site is used, and Google AdSense to show ads on journal and article pages. Both stay off unless you accept, and you can change your mind at any time. How we use cookies · KVKK notice (Türkiye)
Cookie settings
Comments
No comments yet. Be the first to comment on this article.