determination of synthetic phenolic antioxidants in biological fluids based on air-assisted liquid-liquid microextraction followed by gas chromatography-flame ionization detection

Clicks: 148
ID: 248297
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #20 of 20 articles by views in critical care research and practice

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
An air–assisted liquid–liquid microextraction method for the extraction and preconcentration of trace amounts of some synthetic phenolic antioxidants in biological fluids followed by their determination by gas chromatography–flame ionization detection has been reported. In this method the target analytes are extracted into a few microliters of carbon tetrachloride (extraction solvent) from an aqueous solution by aspirating and dispersing the extraction solvent and sample solution mixture by a syringe. After extraction, phase separation is performed by centrifugation and the enriched analytes in the sedimented phase are determined. The parameters affecting the extraction efficiency including the type and volume of extraction solvent, salt addition, extraction times, and pH are investigated in details. Under the optimum extraction conditions, the method shows low limits of detection and quantification between 0.8–1.8 and 2.7-5.6 ng mL–1, respectively. The method is applied to determine some phenolic antioxidants in biological samples and extraction recoveries are ranged from 63 to 81%. Enrichment factors are obtained between 315 and 405. The method shows good linearities in the range of 3–6000 ng mL-1 with the correlation coefficients higher than 0.996. Relative standard deviations are lower than 8% for intra-day (n=6) and inter-day (n=4) precisions. Finally the proposed method is successfully used for determination of the analytes in urine and plasma samples.
Reference Key
farajzadeh2016analyticaldetermination Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Mir Ali Farajzadeh;Maryam Abbaspoura Abbaspour;Mohammad Reza Afshar Mogaddama Afshar Mogaddam;Ali Akbar Alizadeh Nabil Alizadeh Nabil
Journal critical care research and practice
Year 2016
DOI
10.22036/abcr.2016.32616
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.