measurement of rib-eye area by the method of digital images

Clicks: 176
ID: 247638
2012
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #199 of 235 articles by views in european journal of lipid science and technology

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 235 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
This study evaluated the correlation between measurements of rib-eye areas of sheep carcasses by traditional methods and those obtained by scanned images. Thirty pictures of the longissimus dorsi muscle of sheep carcasses were drawn on tracing paper and analyzed for muscle area (rib-eye) using four methods: scanned images, which utilizes the software DDA -Determinador Digital de Áreas (Digital Area Determiner); measurements "A" and "B" applied to the equation: (A/2 × B/2) × π; Planimeter method and rib-eye grid method. All rib-eye area figures were measured five times by each method, setting up a completely randomized experiment with four treatments and five replicates. Data were submitted to analysis of variance and means were compared by the Tukey test, Pearson correlation and linear regression by the SAS software. Easiness and difficulties perceived by the evaluators in the performance of each method were also recorded. The method of scanned images analyzed by the software DDA showed high correlation with the methods traditionally used, and can be considered feasible to determine carcass rib-eye area, with the advantage of being easy to operate, flexible, and economical.
Reference Key
ferreira2012revistameasurement Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Otoniel Geter Lauz Ferreira;Fábio Diniz Rossi;Régis Antônio Teixeira Coelho;Vivian Francieli Fucilini;Marlova Benedetti
Journal european journal of lipid science and technology
Year 2012
DOI
10.1590/S1516-35982012000300047
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.