implant crest module: a review of biomechanical considerations

Clicks: 243
ID: 245319
2012
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #92 of 150 articles by views in Applied and environmental microbiology

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 150 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The success of dental implants has long been established through various studies with a particular emphasis laid on an implant design. Crest module is that portion of a two-piece metal dental implant, designed to hold the prosthetic components in place and to create a transition zone to the load bearing implant body. Its design, position in relation to the alveolar crest, and an abutment implant interface makes us believe that, it has a major role in integration to both hard and soft tissues. Unfortunately, in most clinical conditions, early tissue breakdown leading to soft tissue and hard tissue loss begins at this region. Early crestal bone loss is usually highest during the first year after placement ranging from 0.9 to 1.6mm and averaged 0.05-0.13mm in the subsequent years . Various hypotheses have been stated to reason it however, none has been proved convincingly. In light of this, various attempts have been made to overcome this undesirable bone loss, by varying an implant design, the position, surgical protocol, and the prosthetic options. Irrespective of an implant system and designs that are used, crestal bone loss of up to the first thread is often observed. The purpose of this review is to look into the various designs and treatment modalities, which have been introduced into the crest module of an implant body to achieve the best biomechanical and esthetic result.
Reference Key
aparna2012indianimplant Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;I N Aparna;B Dhanasekar;D Lingeshwar;Lokendra Gupta
Journal Applied and environmental microbiology
Year 2012
DOI
10.4103/0970-9290.100437
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.