assessmentof seismic stability of buildings that have seismicprotection in the form of elastomeric isolators ОЦЕНКА СЕЙСМОСТОЙКОСТИ ЗДАНИЯ С СЕЙСМОЗАЩИТОЙ В ВИДЕ РЕЗИНОМЕТАЛЛИЧЕСКИХ ОПОР

Clicks: 216
ID: 244099
2013
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #49 of 140 articles by views in PsyCh journal

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 140 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Nowadays, various systems of seismic protection are applied to assure seismic protection of buildings and structures, located in earthquake areas. The greatest prevalence and popularity has been attained by the systems of active seismic protection.In this article, the authors study the efficiency of application of an active seismic protection system by taking high-damping rubber elastomeric isolators as an example. Calculations and their comparative analysis were made for a high-rise reinforced concrete building, and their exposure to the seismic impact was examined. Those calculations were made both with and without the application of the active seismic isolation system. Calculations were carried out by means of the linearly-spectral method using Lira software. Maximum relative horizontal moments arising on the top of the building and forces applied to the elements of walls and columns were compared. On the basis of the results of the calculations and their comparative analysis, the conclusion is drawn that elastomeric isolators may be efficiently applied as an active seismic protection system.
Освещены вопросы применения различных систем активной сейсмозащиты, в т.ч. резинометаллические опоры (РМО), для защиты от землетрясений зданий и сооружений, расположенных в сейсмически опасных районах. Рассмотрен линейно-спектральный расчет железобетонного здания с применением системы активной сейсмоизоляции в виде РМО и без нее в программном комплексе «Лира». Произведен сравнительный анализ результатов расчета.
Reference Key
vartanovich2013vestnikassessmentof Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Mkrtychev Oleg Vartanovich;Bunov Artem Anatol’evich
Journal PsyCh journal
Year 2013
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.