application of trickling filter for sewage treatment with high ammonia nitro gen concentration
Clicks: 183
ID: 243467
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
183 views
28 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #119 of 146 articles by views in BMC medical education
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 146 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The article presents the results of research about the possibility of using trickling filter for high ammonia concentration sewage treatment. The study was conducted with the use of reject water generated during anaerobic sewage sludge stabilization in dairy wastewater treatment plant (WWTP. They are usually returned to the beginning of WWTP. The value of BOD in reject water was approximately the same as in domestic and municipal sewage. Ammonia nitrogen concentration was varied from 145,0 to 390,0 mgN-NH4+/l and phosphorus from 16.0 to 38.0 mgP/l. The study used the Gunt test system CE701e, which allows controlling basic parameters of the treatment with trickling filter. Significant reduction of organic matter, total nitrogen and ammonium was observed during treatment. Average removal efficiency of ammonia nitrogen ranged from 73.6 to 80.3%. In the case of the Kjeldahl nitrogen removal efficiencies ranged from 74.4 to 79.8%. Because of the aerobic conditions during the treatment of phosphorus removal efficiency was low and varied from 32.0 to 33.7%. The research confirmed the efficiency of trickling filter for treatment sewage with high concentration of ammonia nitrogen.
| Reference Key |
dbrowski2016inynieriaapplication
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Wojciech Dąbrowski;Magdalena Horysz |
| Journal | BMC medical education |
| Year | 2016 |
| DOI |
10.12912/23920629/62852
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org