penentuan penurunan tegangan berdasarkan minimum spanning tree pada jaringan listrik distribusi primer

Clicks: 266
ID: 241796
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #6 of 7 articles by views in cogent arts & humanities

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Determination of the minimum spanning tree is widely used to solve optimization problems are problems that demand solutions minmum search. In the electricity distribution network, the minimum spanning tree (MST) is used to find the minimum cable length for the system to the power grid becomes more optimal. The use of a minimum weight minimum cable length can be used as a variable for calculating the voltage drop (voltage drop) of an electricity distribution network.  The method used in this research is the process of field observations and data processing. Field observations aims to take some of the coordinates of each pole on the electricity distribution network. While the data processing is done to create a geographic information system that is based on primary data in the form of a power pole coordinates data and secondary data along with the data in the form of electricity distribution networks. Furthermore, the results obtained by the minimum weight of the MST combined with existing data on the electricity distribution networks like cable cross-sectional area, the type of cable used, and the current through the tissue with voltage measurement results from the ends of the network to obtain results penurungan voltage (voltage drop) resulting from each feeder. Results (voltage drop) can be used as a basis for evaluating the electrical distribution network that has been existing, particularly in the City Bontang.
Reference Key
hardianto2015emitorpenentuan Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Hardianto Hardianto
Journal cogent arts & humanities
Year 2015
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.